Document IOP Findings

  1. Expand the IOP panel.
    The Historical IOP data appears in the grid.
  2. To track the reduction between pre-treatment IOP and the IOP during or after treatment, starting with the current encounter:
    1. Click a Baseline IOP field and select an appropriate baseline pre-treatment value from the list or select the top blank line and type in a value.
    2. Enter a Baseline IOP value for OD and OS.
  3. Click the Method field and select the method used for measuring IOP from the list or select the top blank line and type a value.
  4. To enter findings for intraocular pressure using mmHg.
    1. Click the OD field and select a value in the list.
      The list for OS opens automatically.
    2. Select a value for OS.
  5. Enter findings for intraocular pressure using kPa for OD and OS.
    The name of the current user fills the Taken by field.
  6. Type comments in the Comment field.
  7. If the patient was dilated while the measurements were taken, select the Dilated IOP check box.
  8. Click Save.
    If there are values in the IOP Baseline fields, the IOP Reduction fields refresh to display the calculated values for the percentage of reduction in IOP between the baseline IOP values and the values saved for today's encounter.