Map
SNOMED®
Code with the Diabetic Eye Exam Procedure
On the
Data Sets Setup
template
, select
Data Set
and select
Quality Reporting Order Findings xref
.
The existing data set items associated with the
Quality Reporting Order Findings xref
data set appear in the grid.
Select
Add
.
The
Template Data Sets Setup – [New Record]
template opens.
If applicable, select
Diagnosis description
to search and select a diagnosis.
The associated diagnosis code automatically populates.
If applicable, select
Provider
and select a provider from
Dbp Rendering Provider
.
In
xref type
, enter the system reference table name.
In
procedure code
, enter the procedure code.
In
finding value
, enter the physical examination value. For example, Negative, Normal, and so on.
In
code value
, enter the SNOMED code.
In
code system
, enter
SNOMED
.
Select
Save
, and then select
Close
.
The newly configured data set item displays in the
Data Sets Setup
template.
Note:
To add another item, select
Clear For Add
in the
Template Data Sets Setup – [New Record]
template and repeat steps 1 and 2.
View Run-Time Result of Mapping SNOMED Code with the Diabetic Eye Exam Procedure
Map SNOMED® Code with the Diabetic Eye Exam Procedure
NextGen® Adaptive Content Engine Help Enterprise 8.3.1
Associate LOINC® Codes with Procedure Code
On the Data Sets Setup template, select Data Set and select LOINC Codes.The existing data set items associated with the LOINC Codes data set appear in the grid. LOINC Codes data set Select Add.The Template Data Sets Setup – [New Record] template opens. Template Data Sets Setup If applicable, select Diagnosis description to search and select a diagnosis.The associated diagnosis code automatically populates. If applicable, select Provider and select a provider from Dbp Rendering Provider. In Code, enter LOINC code. In System, enter the code type. For example, LOINC to indicate that the code is LOINC code. In Procedure Code, enter CPT or NextGen Compendium Test keys. In Description, enter the description of the procedure code. Select Save, and then select Close.The newly configured data set item displays in the Data Sets Setup template. Note: To add another item, select Clear For Add in the Template Data Sets Setup – [New Record] template and repeat steps 1 and 2. Parent topic: LOINC Data
NextGen® Adaptive Content Engine Help Enterprise 8.3.1
List of Data Sets That Can be Configured
You can configure and manage the following data sets using the Data Sets Setup practice template: Asthma Codes CARD Procedure Orders Other Details Pop-up Clear EF Codes EM psychotherapy Health Promotion Plan Lab Completed Status LOINC Codes Medication Billing Quality Reporting Order Findings xref Nebulizer Treatment Patient Safety Reports PE Copy Forward Excluded Fields PT Exercise PT Modifier 59 Test Codes Test Dates AB History Codes Data Set The AB History Codes data set stores SNOMED codes and descriptions pertinent to abortion focused medical histories. Asthma Codes Data Set CARD Procedure Orders Other Data Set Detail Pop-up Clear Data Set EF Codes Data Set EM Psychotherapy Data Set Health Promotion Plan Data Set Lab Completed Status Data Set LOINC Data Set Medication Billing Data Set Med GCN Mapping The Med GCN Mapping data set enables you to map template level medication with the generic code number (GCN) using the Data Sets Setup practice template. Quality Reporting Order Findin
NextGen® Adaptive Content Engine Help Enterprise 8.3.1
Add Test Code Data Set Items
On the Data Sets Setup template, select Data Set and select Test Codes.The existing data set items associated with the Test Codes data set appear in the grid. Test Codes data set Select Add.The Template Data Sets Setup – [New Record] template opens. Template Data Sets Setup Select Test and select a name that the code or description will be mapped to from the picklist. The picklist displays the list of all test names currently available in the system. The name is used by the practice to identify an order, patient procedure, or lab. Select OK. Note: To enter a test name that is not listed, select the blank line that displays in the picklist and select OK. Type the name in the Test field. Enter one of the following: Codes - Enter the code to be mapped to. The entered code is used by the reference lab or outside study/procedure location to identify the test at their location for ordering or billing purposes. Description - Enter the text to describe the test. The entered text is the descrip
NextGen® Adaptive Content Engine Help Enterprise 8.3.1
Map HCPCS Codes to Nebulization Solution
On the Data Sets Setup template, select Data Set and select Nebulizer Treatment.The existing data set items associated with the Nebulizer Treatment data set appear in the grid. Nebulizer Treatment data set Select Add.The Template Data Sets Setup – [New Record] template opens. Template Data Sets Setup If applicable, select Diagnosis description to search and select a diagnosis.The associated diagnosis code automatically populates. If applicable, select Provider and select a provider from Dbp Rendering Provider. In List Item, enter the solution name to be used in the nebulizer. In Qualifier 2, enter the amount of the nebulized solution to be used. In HCPCS, enter the procedure code. In Units, enter the number of units of the nebulized solution. In Rounding, enter a value that is used to calculate the number of units to submit with the J code for the nebulizer procedure. The Rounding value is used to round-up the value entered in Units when you submit the data for billing. Select Save, an
NextGen® Adaptive Content Engine Help Enterprise 8.3.1
View Run-Time Result of Mapping SNOMED® Code with the Diabetic Eye Exam Procedure
Before you view the run-time result, ensure to add new codes to the Ophthalmology Exams category, if available. Else, create a new category for Ophthalmology Exam, and then add the new codes. In the run-time Intake template, select Specialty as Ophthalmology and Visit Type as Office Visit. Select the Standing Orders link.The Office Services template opens. In the Diagnostic History Entry panel, select Diagnostic study type and then select Ophthalmology Exams from the resulting list. Select Diagnostic Study and select Intermediate eye exam, established patient from Service Item Mstr dbpicklist.The Procedure code automatically appears. Select Date performed and select a date from the calendar. Document other details, if required. Select Add to Grid.The SNOMED code that is mapped to the selected procedure code in the Quality Reporting Order Findings xref data set is updated in the database to get the Quality Reporting credit. Office Services template Parent topic: Map SNOMED Code with the
NextGen® Adaptive Content Engine Help Enterprise 8.3.1
Quality Reporting Order Findings Xref Data Set
The Quality Reporting Order Findings xref data set enables you to map the SNOMED code with the procedure associated with the diabetic eye exam. The mapping of SNOMED code with the procedure enables you to get the credit for Quality Reporting-CMS 131 measure. Map SNOMED Code with the Diabetic Eye Exam Procedure Add New Codes to the Ophthalmology Exams Category Edit Quality Reporting Order Findings xref Data Set Items Remove Quality Reporting Order Findings xref Data Set Items Parent topic: List of Data Sets That Can be Configured